Every visitor asks the same thing at the door: "Is there really no window in here?" There is not. The room runs at 23 °C ± 1 and 45% relative humidity, and a window in Guangzhou in July is a 15-degree argument with that.
Polymer shrinks as it cools. A 0.02 mm needle is mostly shrinkage management — you are not molding a needle, you are molding a slightly oversized needle that will become exact when it cools in a steel cavity held to within one degree.
Put a window in, and the afternoon sun moves the cavity temperature by two degrees. Nothing looks wrong. The first 200 shots are fine. Then needle length drifts 0.015 mm on the side of the mold facing the glass, and because the drift is gradual, it passes a spot check and fails a customer's caliper six weeks later.
We keep the room sealed and the light artificial for the same reason a lab keeps its door shut. It is not romance about precision — it is that Guangzhou weather is a variable I cannot control, so I remove it.