Year one failures are manufacturing defects. Year two failures are design and handling, and they cluster into five groups.
1. Thread wear between head and handle. The head clicks on but sits looser than it did. Cause: moulded threads, no metal insert. Fix: a stainless insert in the handle, about USD 0.22 per unit, decided at tooling time. Retrofitting is not possible.
2. Seal failure in the serum cartridge. Usually the butyl stopper, usually after temperature cycling in transit. Fix: a thicker stopper flange plus a 40 °C/75% RH stability run before shipping, not after.
3. Plating wear at the tip. Thin gold plus a clinic's alcohol routine. Visible in month 9–14. Fix: 3 micron minimum, or stop claiming gold.
4. Carton crush in the last mile. Not our box, the courier's sorting belt. Fix: an inner tray with 8 mm clearance and a 1.2 m drop test on the packed carton.
5. Instruction drift. The clinic changes staff, nobody reads the insert, and pressure goes up. Fix: a single pictogram on the head's blister, not a paragraph in a leaflet.
Every one of these is cheaper to design out than to service. That is the whole argument for paying attention at tooling stage.